Skip to content

VER - Video Equipment Rentals
Search
Customer Service

800-794-1407

24/7 Technical Support

888-584-TECH

Products

SSA-324

Enlarge Image

Additional Images:

RTS

SSA-324

RTS SSA-324 4-Wire to 2-Wire Converter

This system-to-system adapter (or interface) interconnects the voice signals between different intercom systems. In addition, it can optionally interconnect "Calls" or tally signals between systems. Each SSA-324 includes two two-wire to four-wire converters.

It can also function as a two-wire to two-wire interface by interconnecting the two individual interfaces at the four-wire level. The SSA-324 does two voice channels when used as a dual two-wire to four-wire interface, and one voice channel when functioning as a two-wire to two-wire interface. In addition, there is a call light option board available.

Product Weight:  2.75 lbs
Dimensions:  1.72”H x 8.19”W x 8.00”D

Technical Tools

Manufacturer Specs

Operating Levels
-20 dBu to +0 dBu, nominal

Two-Wire Output
Impedance: 5,000Ω 20% single ended, 10.000Ω 20% differential
Operating Level: 0.1 mA to 10 mA, nominal

Four-Wire Input
Impedance: 10,000Ω minimum single ended, 20,000Ω minimum differential operating Levels: -10 dBu to +8 dBu, nominal

Four-Wire Output
Impedance: single ended or differential
Operating Levels: -10 dBu to + 8 dBu, nominal

Transfer Functions (Duck Level set to no ducking)
Voltage Gain, Four-Wire In to Two-Wire Out*
Level Pot 100% rotation: 3 dB
Level Pot 50% rotation: -15 dB 4 dB

Transfer Functions (Duck Level set to no ducking)

Voltage Gain, Two-Wire In to Four-Wire Out**
Level Pot 100% rotation: 22 dB 3 dB
Level Pot 50% rotation: 8 dB 4 dB

Frequency Response (Reference: 1 KHz, 0 dBu input)

Four-Wire Input to Two-Wire Output: 200 Hz to 5 KHz, +1,-4 dB, typical
Two-Wire Input to Four Wire Output: 250 Hz to 5 KHz, +1, -4 dB, typical

Signal-to-Noise Ratio (Reference: 1 KHz, 0 dBu at two-wire)

Two-Wire to Four-Wire: -60 dB
Four-Wire to Two-Wire: -60 dB

Crosstalk (Reference: 1 KHz, 0 dBu)

System A to System B,
Two-wire to Two wire
200 Hz to 5 KHz: -50 dB,

Environmental
Temperature
  Operating: 32°F to 122°F
  Storage: -40°F to 167°F
Humidity: 0 to 95%. non-condensing

Mains Voltage
Standard: 120 volts 10%, 50-60 Hz
*P Option: 230 volts 10%, 50-60 Hz
#D Option: 100 volts + 10%. -5%, 50-60 Hz

Mains Amperes
Standard: 0.20A @ 120 volts 10%, 50-60 Hz
*P Option: 0.10A @ 230 volts 10%. 50-60 Hz
#D Option: 0.22A @ 100 volts +10%,.-5%. 50-60 Hz

Finish
Thermoplastic front panel, aluminum case, light gray finish.

Nulling
Manual