Skip to content

VER - Video Equipment Rentals
Search
Customer Service

800-794-1407

24/7 Technical Support

888-584-TECH

Products

VRT

Enlarge Image

Additional Images:

Lectrosonics

VRT

Lectrosonics VRT Tracking Receiver Module

This module is used with the Lectrosonics VRM Venue Modular Receiver. It is a triple conversion, frequency synthesized UHF receiver controlled by the DSP in the host assembly. Advanced frequency tracking front-end filters make it excellent for congested and hostile RF environments.


Technical Tools

Manufacturer Specs

Operating Frequencies (MHz) for Receiver Modules:       
Block 21 537.600 - 563.100       
Block 22 563.200 - 588.700       
Block 23 588.800 - 607.900 and 614.100 - 614.300       
Block 24 614.400 - 639.900       
Block 25 640.000 - 665.500       
Block 26 665.600 - 691.100       
Block 27 691.200 - 716.700       
Block 28 716.800 - 742.300       
Block 29 742.400 - 767.900
       
Digital latency:
• 1.5 mS (receiver only - hybrid mode)       
• 3.0 mS (receiver and transmitter in hybrid mode)       
• 3.0 mS (receiver only - analog compatibility mode)       
The 3.0 mS latency in analog compatiblity mode time aligns the audio from analog and hybrid transmitters when they are used together in a Venue system.   
   
Frequency selection: 256 frequencies in 100 kHz steps per 25.5 MHz frequency block       
Channel Spacing: 100 kHz       
Dual Block Range: Built in antenna mulitcoupler covers a two block range.       
Pilot tone: 25 to 32 kHz; 5kHz deviation; unique pilot tone frequency for each selected carrier frequency (Hybrid mode)       
Deviation: ± 75 kHz (max) (Hybrid mode)       
Receiver Type: Triple conversion superheterodyne       
Frequency Stability: ±0.001%
       
Front End Bandwidth:       
VR Master: 50 MHz @ -3 dB       
VRS Module: 30 MHz @ -3 dB       
VRT Module: 11 MHz @ -3 dB   
   
Sensitivity (20 dB Sinad): 0.9 uV       
AM Rejection: >60 dB, 2 uV to 1 Volt       
Image and Spurious Rejection: 85 dB       
Third Order Intercept: VRS:+0 dBm, VRT: +6 dBm       
Diversity Methods: Switched, ratio and frequency       
FM Detector: Digital pulse counting detector @ 300 kHz       
Audio Performance (overall system):       
Frequency Response: 32 Hz to 20 kHz (+/-1dB), overall system (400 Series mode)       
THD: 0.2% (typical) (400 Series mode)       
       
SNR at receiver output (dB) (in Hybrid operating mode):       
SmartNR     No Limiting     W/ Limiting       
OFF               103.5               108.5
NORMAL       107                 111.5
FULL              108.5              113
       
LCD: 122x32 graphical display       
Power Requirements: 10 to 18 VDC; 12 W max., (1.2 A at 10 VDC to .67 A @18 VDC)