Meyer CQ-2 Narrow Coverage Main Loudspeaker

This self-powered, phase-corrected reinforcement loudspeaker offers precise, high-Q coverage. The frequency response of 40 Hz to 16 kHz is uniform over the entire coverage area in both the horizontal and vertical axes, with no side lobes even when measured at a one-sixth octave frequency resolution.

The CQ-2 loudspeaker’s unique combination of arrayability, precise pattern control, compact size, low distortion and high power make it suitable for a wide variety of installed and rental applications. As stand-alone or in arrays, it can be used as the main PA in small to mid-sized auditoriums, houses of worship, clubs, and hotel ballroom settings, and is highly effective in delayed fill applications for arenas and outdoor concert systems.

Product Weight:  150 lbs
Dimensions:  21"W x 30"H x 22.2"D

Technical Tools

Manufacturer Specs

Acoustical       
Operating Frequency Range1: 35 Hz - 18 kHz   
Frequency Response2: 40 Hz - 16 kHz ±4 dB   
Phase Response: 50 Hz - 16 kHz ±90°   
Maximum Peak SPL3: 139 dB   
Dynamic Range: >110 dB   
       
Coverage: 50° Horizontal x 40° vertical   
       
Crossover4: 900 Hz   
       
Transducers       
Low Frequency       
   One 15" cone driver       
   Nominal impedance: 8 Ω       
   Voice coil size: 3"       
   Power-handling capability: 600 W (AES)5      
High Frequency       
   One 4" compression driver       
   Nominal impedance: 8 Ω       
   Voice coil size: 4"       
   Diaphragm size: 4"       
   Exit size: 1.5"     
   Power handling capability: 250 W (AES)5       
       
Audio Input       
Type: Differential, electronically balanced   
Maximum Common Mode Range: ±15 V DC, clamped to earth for voltage transient protection   
Connectors: Female XLR input with male XLR loop output or VEAM all-in-one     (integrates AC, audio and network)   
Input Impedance: 10 kΩ differential between pins 2 and 3   
Wiring       
   Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies   
   Pin 2: Signal +       
   Pin 3: Signal - (Polarity can be changed on user panel)       
   Case: Earth ground and chassis       
DC Blocking: None on input; DC blocked through signal processing   
CMRR: >50 dB, typically 80 dB (50 Hz - 500 Hz)   
RF Filter: Common mode: 425 kHz; Differential mode: 142 kHz   
TIM Filter: <80 kHz, integral to signal processing   
Nominal Input Sensitivity: 0 dBV (1 V rms, 1.4 V pk) continuous average is typically the onset of    limiting for noise and music.
Input Level: Audio source must be capable of producing a minimum of +20 dBV (10 V rms, 14 V pk) into 600 Ω to produce maximum peak SPL over the operating bandwidth of the loudspeaker.
       
Amplifier       
Type:Two-channel complementary MOSFET output stages (class AB/H)   
Output Power6: 1240 W (620 W/channel)   
THD, IM, TIM: <.02%   
Load Capacity: 8 Ω each channel   
Cooling: Forced air cooling, two fans total (one ultrahigh-speed reserve fan)   
       
AC Power       
Connector: 250 V AC NEMA L6-20 (twistlock) inlet, IEC 309 male inlet, or VEAM   
Voltage Selection: Automatic, two ranges, each with high-low voltage tap (uninterrupted)   
Safety Agency Rated Operating Range: 95 V AC - 125 V AC; 208 V AC - 235 V AC; 50/60 Hz   
Turn-on and Turn-off Points: 85 V AC - 134 V AC, 165 V AC - 264 V AC; 50/60 Hz   
Current Draw
   Idle Current: 0.640 A rms (115 V AC); 0.320 A rms (230 V AC); 0.850 A rms (100 V AC)   
   Max Long-Term Continuous Current (>10 sec): 8 A rms (115 V AC); 4 A rms (230 V AC); 10 A rms (100 V AC)   
   Burst Current (<1 sec): 15 A rms (115 V AC); 8 A rms (230 V AC); 18 A rms (100 V AC)   
   Ultimate Short-Term Peak Current Draw: 22 A pk (115 V AC); 11 A pk (230 V AC); 25 A pk (100 V AC)   
   Inrush Current: 7 A pk (115 V AC); 7 A pk (230 V AC); 10 A pk (100 V AC)   

Physical

Enclosure: All birch plywood
Finish: Black textured
Protective Grille: Perforated steel grille with charcoal-grey foam
Rigging: Aircraft pan fittings, two on both top and bottom. Working load for each fitting is 500 lbs, which is 1/5 the cabinet breaking strength (with straight tensile pull).
       
RMS Network (optional): Equipped for two conductor twisted-pair network, reporting amplifier operating parameters to system operator’s host computer.
       
Notes
1. Recommended maximum operating frequency range. Response depends on loading conditions and room acoustics.   
2. Free field, measured with 1/3-octave frequency resolution at 4 meters.     
3. Measured with music at 1 meter.   
4. At this frequency, the low- and high-frequency transducers produce equal sound pressure levels.   
5. Power handling is measured under AES standard conditions: transducer driven continuously for two hours with band-limited noise signal having a 6 dB peak-average ratio.   
6. Amplifier wattage rating is based on the maximum unclipped burst sine-wave rms voltage the amplifier will produce into the nominal load impedance. Both channels 70 V rms (100 V pk) into 8 ohms.